green laser pointer can be sold on the website.
Select the 50% duty cycle square wave modulation and the use of sine wave (or triangular wave) modulation output as shown in Figure 4-4 shows the electrical pulse shape, pulse rise time is less than the fall time, this is because when modulation frequency is high, the cycle of the modulation signal is less than the chip pulse modulation response of the constant current source rise time and fall time and shown in Figure 4-3, this time, the output pulse is mainly affected by the modulation of the chip itself, affect the response time, while little effect of the modulated signal waveform relaxation oscillation does not appear. The modulation PIN21 when three different waveform modulation the output diagram. Square wave frequency modulation output diagram. This design uses a constant current source driver chip HY6340 as the core components of the power supply.temperature, increases the threshold current of semiconductor lasers; the temperature is increased to 25 degrees, the threshold current increase twice as large.
The slow start of the LD laser power supply circuit. LD laser power arbitrary opening and closing without damage, you can arrange for a slow start circuit LD laser power supply circuit, so that the power to open and close the forward current of the LD laser iF can slow over time, changes, thus ensuring the LD The laser does not damage the power is turned on and off. The slow start circuit schematic shown in Figure 1. The figure, Vi is the input DC voltage stability, K, closed the power is turned on Vi access instantly. RC charging circuit, with the rise of charge voltage on the capacitor C (negative), the PNP type transistor T1 deadline to enter the conduction state until saturated conduction. The selection of green laser pointer is based on the actual needs and real requirements.Assume that Vi is 24V, the T2 tube, beta = 100, and suddenly Figure T1, the T2 tube turn-on voltage of the VBE (on), and L the pressure drop, the choice of Rs = 2.4kΩ, RW, potentiometer 0 ~ 5.6kΩ (adjustable resistor). LD current control system of the current is adjustable. In the actual laser blood therapy instrument, if you use a variable resistor to adjust the output current of the iF, there will be may be due to the frequent rotation of the potentiometer and some point of contact from the slip between the film and the resistance of the wire, so that the variable resistor circuit point in the adjustment process.
No comments:
Post a Comment